For full functionality of this site it is necessary to enable JavaScript.

Ống phát hiện Carbon dioxide CO2 trong khí nén Gastec 2A (250 ~ 3000 ppm, không dùng bơm)


Không cần dùng thêm bơm, lắp trực tiếp vào đầu ra van tiết lưu khí nén
Vạch chỉ thị: 250 ~ 3000 ppm
Thang đo: 250 ~ 3000 ppm
Tốc độ lấy mẫu: 100mL/min(500mL)
Thời gian lấy mẫu:  5 phút
Chuyển đổi màu: Orange Yellow → Yellow
Phương trình phản ứng: CO2 + 2KOH → K2CO3 + H2O
Hệ số biến đổi: 10% (250 ~ 1000 ppm) , 5% (1000 ~ 3000 ppm)
Số ống trong hộp: 10

Chi tiết

 

Performance
Measuring Range 250 to 3000 ppm
Sampling Rate 100mL/min(500mL)
Correction Factor 1
Sampling Time 5 minutes
Colour Change Orange Yellow → Yellow
Reaction Principle CO2 + 2KOH → K2CO3 + H2O
Coefficient of Variation 10% (for 250 to 1000 ppm) , 5% (for 1000 to 3000 ppm)
Shelf Life 2 Years
Corrections for temperature Unnecessary for 0 to 40℃
Corrections for humidity Unnecessary for R.H.0 to 90%
Store the tubes at cool and dark place.
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
5000 ppm 30000 ppm -

Catalog

Performance
Measuring Range 200 to 3000 ppm
Sampling Rate 100mL/min(150mL)
Correction Factor 1
Sampling Time 1.5 minutes
Colour Change Pale blue → Purple
Reaction Principle CO2 + N2H4 → NH2NHCOOH
Coefficient of Variation 10% (for 200 to 1000 ppm) , 5% (for 1000 to 3000 ppm)
Shelf Life 3 Years
Corrections for temperature Unnecessary for 0 to 40℃
Corrections for humidity Unnecessary for R.H.0 to 90%
Store the tubes at cool and dark place.
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
5000 ppm 30000 ppm -

Catalog

 

Performance
Measuring Range 500 to 5000 ppm
Sampling Rate 300mL/min(300mL)
Correction Factor 1
Sampling Time 1 minutes
Detecting Limit 300ppm
Colour Change Green → Purple
Reaction Principle H2O + Mg(ClO4)2 → Mg(ClO4)2 H2O
Coefficient of Variation 10% (for 500 to 1000 ppm), 5% (for 1000 to 5000 ppm)
Shelf Life 2 Years
Corrections for temperature Unnecessary for 0 to 40℃
Store the tubes at cool and dark place.
Calibration gas generation Bubbling method

Airtec tube - Compressed breathing air detector tubes

Airtec Tube for Cylinder / Compressed Breathing Air / Air Line Test.
Airtec tubes are a convenient and simple system for testing of a gas cylinder, compressed breathing air and air line. Industrial operations often produce, or are performed in the presence of harmful airborne contaminants. When self contained breathing apparatus or other devices are used for respiratory protection, the quality of the breathing air requires special attention. Contaminants entering the compressor or contaminants generated by the compressor or cylinder can be harmful to the worker and the respiratory equipment.
 




Measurement procedure:


1.Install a reducer pressure with gauge and flow metre to a cylinder, compressor or air line and adjust the flow metre the required setting.
  2.Break tips off a fresh detector tube in the tube tip breaker and insert a tube into a tube holder.
 
3.Attach the rubber tube holder to the flow metre outlet. Make certain the tube arrowon the tube pointing in a down direction.
  4.Turn on the cylinder or compressor and confirm the flow metre according to each Airtec tube specifications.
 
5.Time the flow rate with a stopwatch.
  6.As soon as sampling time has elapsed turn off the cylinder or compressor, and remove the tube from the tube holder and then read the colour change layer immediately.

 