Thermonics ATS-810E-M Thermostream (-80 ~ + 225°C)
Manufacturer: Thermonics Model: ATS-810E-M P/N: SL11690A - Contact
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222)730.39.68
HCM city: (028) 38.119.636
Description
The ATS Series temperature forcing systems are designed for the demanding 24/7 production environment. They provide fast, precise, and robust production-level testing and conditioning of electronic components, boards and modules. Capable of ultra-low temperatures without the use of Liquid Nitrogen (LN2) or Liquid Carbon Dioxide (LCO2).
Built with proven reliability and supported worldwide, the ATS Series is ideal for any mobile temperature testing environment.
Performance
Temperature Range: -80 ~ +225°C, No LN2 or LCO2 Required
Transition Rates
Heating: -55 to +125°C, <10 seconds
Cooling: +125 to -55°C, <10 seconds
System Airflow Output: 4 to 18scfm (1.9 to 8.5 l/s) Continuous
Temperature control
Temperature Display & Resolution: +/- 0.1°C
Temperature Accuracy: 1.0°C (when calibrated against NIST standard)
DUT Temperature Control: Proprietary control algorithm enables DUT temperature to be directly controlled
DUT Sensor Ports: Thermocouples (type T & K)
Power: 200 - 250 VAC (230V nominal), 60Hz, 30 amp, 1phase
Compressed air
Clean, Dry Air (CDA): Filtered to 5 micron particulate contamination.
Oil Content: <0.1 ppm, by weight, filtered to 0.01 micron oil contaminant.
Dewpoint: <10°C @6.2 bar (90PSI)
Air Supply Pressure: 6.2 to 7.6 bar (90 to 110 PSIG)
Total Air Flow Rate Required: 7.1 to 14.2 l/s (15-30 scfm), 11.8 l/s (25 scfm) nominal
Air Supply Temperature: +20°C to +25°C; +22°C nominal
Operating environment
Operating Temperature: +20°C ~ +28°C; +23°C nominal
Humidity: 0 ~ 60%; 45% nominal
Noise Level: <65dBA